kopf
seite
germanenglishKoralewski Industrie-Elektronik oHG | Brigitta 26 | 29313 Hambühren | Tel +49 (0)5084 / 980050 | info@koralewski.de
impressum

Warning: mysql_connect() [function.mysql-connect]: Access denied for user: 'root@localhost' (Using password: YES) in /user/kora/public_html/english/produkte/includes/suchen.php on line 12

DMZ-8E Flow Volume Counter

back
The DMZ-8E Flow Volume Counter is used for dosing or filling preset fluid volumes with two limiting values. This unit also captures the flow rate and can therefore be used as an adjustable flow monitor. A freely configurable current output can be assigned either to the volume or to the speed. Commercially available a flow sensors, which emit pulses proportional to the volume, are used as signal generators. These could be contact-equipped water meters or impeller wheel recorders, for example. Multiple configuration and setting options enable the user to adjust the unit precisely to the given application.

Downloads


pdf data sheet (english)

pdf description (english)

pdf data sheet (german)

pdf description (german)

Technical Data

Power supply
230 V AC +5%/-10%, 50 Hz

Power consumption
approx. 15 VA

Fuse protection
4 A mT

Inputs
10 V DC,
I approx. 9 mA
contact resistance: max. 1.5 kOhm

Relay outputs
5 x neutral, max. 230 V AC, 2 A

Current output
0(4)...20 mA, max. load 400 Ohm
linearity: 0.5% FS

Transmitter
water meter with neutral contact
or NPN open collector or vane-type sensor with NPN open collector

Transmitter factor
0.01 ... 9999 pulses / liter

max. transmitter frequency
500 Hz (adjustable)
programmable contact de-bouncing
via maximum sender frequency

Climatic Conditions
acc. to DIN EN 60204-1 ( 05-2010 )
Ambient Temperature
operation:              -20 ... +55 °C
transport/storage:  -25 ... +55 °C

Housing
control panel housing per DIN 43700
with transparent cover up to IP65 in front
of the control panel

Dimensions
W / H / D : 144 x 72 x 116.6 mm
Framing dimensions
W / H : 137 x 67 mm

Ordering information:
DMZ-8E: E1720